Đồng hồ áp suất ATLANTIC Đồng hồ áp suất ATLANTIC

APPLICATIONS Measure all liquid and gas process media compatible with stainless steel. The glycerin / silicon oil filled type is especially used for measuring points in vibrational and highly dynamic pressure load. Particularly used in chemical, petrochemical, food industry, biochemistry and any rush industries. SPECIFICATIONS SPECIFICATIONS Dial Diameter 1½‖ (40mm);2‖ (50mm);2½‖ (63mm);3‖ (75mm);4‖ (100mm);6‖ (150mm) 8‖ (200mm);10‖ (250mm) Case : Stainless steel 304, IP65 Crimp bezel for dial Φ1½‖ ~ 4‖;Bayonet bezel for dial Φ2½‖ ~ 10‖ Lens Acrylic or glass for dial Φ1½‖ ~ 4‖ ;Safety glass for dial Φ 4‖ ~ 10‖ Dial Aluminum, black and red markings on white background, dial arc 270° Measuring Principle Bourdon Tube, stainless steel 316 C form tube for ≦ 70 kg/cm2 ;Helical form tube for >70 kg/cm2 Movement Stainless steel Pointer Aluminum, black, adjustable pointer available for dial Φ 4‖ ~ 10‖ Connection Male thread 1/8‖, 1/4‖, 3/8‖, 1/2‖ PT(BSPT) / NPT / PF(BSP), stainless steel 316 Filling Without (dry);glycerin filled;silicon oil filled Accuracy ±2% F.S. for Φ1½‖ & 2‖ ; ±1.5% F.S. for Φ2‖ ~ 3‖ ; ±1% F.S. for Φ3‖ ~ 10‖ Temperature Limit Dry:medium +100℃;ambient -20 to +60℃ Glycerin filled:medium +100℃;ambient +10 to +60℃ Silicon oil filled:medium +100℃;ambient -45 to +60℃ <Silicon oil filled type can be for medium +200℃only if the case and connection are welded together (argon-arc welding), available forΦ2½‖ ~ 10‖.> Pressure Range positive 0 / 1 ~ 0 / 1000 kg/cm2 negative 0 / -76 cmHg (relative vacuum) compound -76cmHg / 0 / 1 ~ -76cmHg / 0 / 20 kg/cm2 <other units available, e.g. psi, bar, MPa…etc.> OPTIONS - Safety glass lens for dial Φ2-1/2‖ & 3‖ - Blow-out disk by back for dial Φ4‖~10‖ - Special male or female thread connections - Cleanness for oxygen, acetylene, hydrogen…etc. dangerous media service - Restrictor on connection to alleviate pressure pulsation - Device of red pointer which can leave behind on max. pressure - Device of diaphragm, electrical contacts or accessories

Khuyến mại :
Bảo hành : 12 tháng
S000556 Đồng Hồ Áp Lực Số lượng: 1 cái
Cloud Zoom small image
˂
˃


  • Đồng hồ áp suất ATLANTIC

  • Đăng ngày 03-11-2016 12:39:47 AM - 360 Lượt xem
  • APPLICATIONS Measure all liquid and gas process media compatible with stainless steel. The glycerin / silicon oil filled type is especially used for measuring points in vibrational and highly dynamic pressure load. Particularly used in chemical, petrochemical, food industry, biochemistry and any rush industries. SPECIFICATIONS SPECIFICATIONS Dial Diameter 1½‖ (40mm);2‖ (50mm);2½‖ (63mm);3‖ (75mm);4‖ (100mm);6‖ (150mm) 8‖ (200mm);10‖ (250mm) Case : Stainless steel 304, IP65 Crimp bezel for dial Φ1½‖ ~ 4‖;Bayonet bezel for dial Φ2½‖ ~ 10‖ Lens Acrylic or glass for dial Φ1½‖ ~ 4‖ ;Safety glass for dial Φ 4‖ ~ 10‖ Dial Aluminum, black and red markings on white background, dial arc 270° Measuring Principle Bourdon Tube, stainless steel 316 C form tube for ≦ 70 kg/cm2 ;Helical form tube for >70 kg/cm2 Movement Stainless steel Pointer Aluminum, black, adjustable pointer available for dial Φ 4‖ ~ 10‖ Connection Male thread 1/8‖, 1/4‖, 3/8‖, 1/2‖ PT(BSPT) / NPT / PF(BSP), stainless steel 316 Filling Without (dry);glycerin filled;silicon oil filled Accuracy ±2% F.S. for Φ1½‖ & 2‖ ; ±1.5% F.S. for Φ2‖ ~ 3‖ ; ±1% F.S. for Φ3‖ ~ 10‖ Temperature Limit Dry:medium +100℃;ambient -20 to +60℃ Glycerin filled:medium +100℃;ambient +10 to +60℃ Silicon oil filled:medium +100℃;ambient -45 to +60℃ <Silicon oil filled type can be for medium +200℃only if the case and connection are welded together (argon-arc welding), available forΦ2½‖ ~ 10‖.> Pressure Range positive 0 / 1 ~ 0 / 1000 kg/cm2 negative 0 / -76 cmHg (relative vacuum) compound -76cmHg / 0 / 1 ~ -76cmHg / 0 / 20 kg/cm2 <other units available, e.g. psi, bar, MPa…etc.> OPTIONS - Safety glass lens for dial Φ2-1/2‖ & 3‖ - Blow-out disk by back for dial Φ4‖~10‖ - Special male or female thread connections - Cleanness for oxygen, acetylene, hydrogen…etc. dangerous media service - Restrictor on connection to alleviate pressure pulsation - Device of red pointer which can leave behind on max. pressure - Device of diaphragm, electrical contacts or accessories

    Khuyến mại :
    Bảo hành : 12 tháng


Số lượng
Số lượng: 1 cái

APPLICATIONS
 Measure all liquid and gas process media 
compatible with stainless steel.
The  glycerin  /  silicon  oil  filled  type  is 
especially  used  for  measuring  points  in
vibrational  and  highly  dynamic  pressure 
load. Particularly used in chemical, 
petrochemical, food industry, biochemistry 
and any rush industries.
 SPECIFICATIONS 
SPECIFICATIONS
Dial Diameter 1½‖ (40mm);2‖ (50mm);2½‖ (63mm);3‖ (75mm);4‖ (100mm);6‖ (150mm)
8‖ (200mm);10‖ (250mm)
Case : Stainless steel 304, IP65
Crimp bezel for dial Φ1½‖ ~ 4‖;Bayonet bezel for dial Φ2½‖ ~ 10‖
Lens  Acrylic or glass for dial Φ1½‖ ~ 4‖  ;Safety glass for dial Φ 4‖ ~ 10‖
Dial  Aluminum, black and red markings on white background, dial arc 270°
Measuring Principle Bourdon Tube, stainless steel 316 C form tube for ≦ 70 kg/cm2
;Helical form tube for  >70 kg/cm2
Movement  Stainless steel Pointer  Aluminum, black, adjustable pointer available for dial Φ 4‖ ~ 10‖
Connection  Male thread 1/8‖, 1/4‖, 3/8‖, 1/2‖ PT(BSPT) / NPT / PF(BSP), stainless steel 316
Filling  Without (dry);glycerin filled;silicon oil filled
Accuracy  ±2% F.S. for Φ1½‖ & 2‖  ;  ±1.5% F.S. for Φ2‖ ~ 3‖  ;  ±1% F.S. for Φ3‖ ~ 10‖
Temperature Limit Dry:medium +100℃;ambient -20 to +60℃
Glycerin filled:medium +100℃;ambient +10 to +60℃
Silicon oil filled:medium +100℃;ambient -45 to +60℃
<Silicon oil filled type can be for medium +200℃only if the case and connection 
are welded together (argon-arc welding), available forΦ2½‖ ~ 10‖.>
Pressure Range positive 0 / 1 ~ 0 / 1000 kg/cm2
negative 0 / -76 cmHg (relative vacuum) compound -76cmHg / 0 / 1 ~ -76cmHg / 0 / 20 kg/cm2
<other units available, e.g. psi, bar, MPa…etc.>
OPTIONS
- Safety glass lens for dial Φ2-1/2‖ & 3‖
- Blow-out disk by back for dial Φ4‖~10‖
- Special male or female thread connections
- Cleanness for oxygen, acetylene, hydrogen…etc. dangerous media service
- Restrictor on connection to alleviate pressure pulsation
- Device of red pointer which can leave behind on max. pressure
- Device of diaphragm, electrical contacts or accessories
 